交换机 IE-4000系列
Product number |
Total ports |
GE combo uplinks (4G)1 |
Additional combo ports |
RJ-45 copper ports (T) |
SFP fiber ports (S) |
PoE/PoE+ ports (P, GP), Maximum PoE power budget |
Default software |
IE-4000-4TC4G-E |
8 |
All models have 4GE combo uplinkports |
4 (FE) |
|
|
|
All models ship with LAN Base feature set2 |
IE-4000-8T4G-E |
12 |
|
8 (FE) |
|
|
||
IE-4000-8S4G-E |
12 |
|
|
8 (FE) |
|
||
IE-4000-4T4P4G-E |
12 |
|
4 (FE) |
|
4 (FE), 125W |
||
IE-4000-16T4G-E |
20 |
|
16 (FE) |
|
|
||
IE-4000-4S8P4G-E |
16 |
|
|
4 (FE) |
8 (FE), 125W |
||
IE-4000-8GT4G-E |
12 |
|
8 (GE) |
|
|
||
IE-4000-8GS4G-E |
12 |
|
|
8 (GE) |
|
||
IE-4000-4GC4GP4G-E |
12 |
4 (GE) |
|
|
4 (GE), 125W |
||
IE-4000-16GT4G-E |
20 |
|
16 (GE) |
|
|
||
IE-4000-8GT8GP4G-E |
20 |
|
8 (GE) |
|
8 (GE), 240W |
||
IE-4000-4GS8GP4G-E |
16 |
|
|
4 (GE) |
8 (GE), 125W |
Product number |
Wattage |
Rated nominal input operating range |
Supported input voltage operating range |
power output |
PoE/PoE+ support |
Use case scenario |
PWR-IE170W- PC-AC= |
170W |
AC 100-240V/2.3A 50-60Hz or DC 125-250V/2.1A |
AC 90-264V or DC 106-300V |
54VDC/3.15A |
Yes |
Maximum PoE/PoE+ port support in a AC or high DC environment1 |
PWR-IE170W- PC-DC= |
170W |
DC 12-54V/2.3A |
DC 10.8-60V |
54VDC/3.15A |
Yes |
Maximum PoE/PoE+ port support in a DC environment1 |
PWR-IE50W- AC= |
50W |
AC 100-240V/1.25A 50-60Hz |
AC 90-264V or DC 106-300V |
24VDC/2.1A |
No |
No PoE/PoE+ support needed in an AC or DC environment |
PWR-IE50W- AC-IEC= |
50W |
AC 100-240V/1.25A 50-60Hz |
AC 90-264V |
24VDC/2.1A |
No |
No PoE/PoE+ support needed when IEC plug is desired |
PWR-IE65W- PC-AC= |
65W |
AC 100-240V/1.4A 50-60Hz |
AC 90-264V |
54VDC/1.2 A |
Yes |
Minimum (1~2 port) PoE support needed in an AC or high DC environment2 |
PWR-IE65W- PC-DC= |
65W |
DC 24-48VDC/4.5A |
DC 18-60V |
54VDC/1.2 A |
Yes |
Minimum (1~2 port) PoE support needed in a DC environment2 |
Description |
Specification |
Hardware |
● 1GB DRAM
● 128-MB onboard flash memory
● 1-GB removable SD flash memory card
● Mini-USB connector
● RJ-45 connector
|
Alarm |
● Alarm I/O: two alarm inputs to detect dry contact open or closed, one alarm output relay
|
Power Input |
● Redundant DC input voltage with operating range: nominal 9.6 to 60VDC
● Maximum DC input current:
3.7A - IE-4000-4T4P4G-E, IE-4000-8T4G-E, IE-4000-8GT4G-E, IE-4000-16T4G-E
4.3A - IE- 4000-4GC4GP4G-E, IE-4000-4TC4G-E, IE-4000-4S8P4G-E,
IE-4000-4GS8GP4G-E, IE-4000-16GT4G-E, IE- 4000-8GT8GP4G-E
5A - IE-4000-8S4G-E, IE-4000-8GS4G-E
|
Power consumption |
● IE-4000-4T4P4G-E, IE-4000-8T4G-E, IE-4000-8GT4G-E, and IE-4000-16T4G-E: 35W
● IE-4000-4GC4GP4G-E, IE-4000-4TC4G-E, IE-4000-4S8P4G-E, IE-4000-4GS8GP4G-E, and IE-4000-16GT4G- E: 40W
● IE-4000-8S4G-E, IE-4000-8GS4G-E: 42W
● These numbers are measured at 9.6V and do not include PoE power consumption
|
Dimensions (H x W x D) |
● All IE 4000 models have the following dimensions: 6.12 x 6.12 x 5.09 in. (155.4 x 155.4 x 129.2 mm)
● PWR-IE170W-PC-AC=: 5.93 x 3.72 x 5.60 in. (150.6 x 94.5 x 142.2)
● PWR-IE170W-PC-DC=: 5.93 x 4.47 x 5.75 in. (150.6 x 113.5 x 145.8)
● PWR-IE50W-AC=: 5.8 x 2.0 x 4.4 in. (147 x 51 x 112 mm)
● PWR-IE50W-AC-IEC=: 5.8 x 2.0 x 4.4 in. (147 x 51 x 112 mm)
● PWR-IE65W-PC-AC=: 5.9 x 2.6 x 4.6 in. (150 x 66 x 117 mm)
● PWR-IE65W-PC-DC=: 5.9 x 2.6 x 4.6 in. (150 x 66 x 117 mm)
|
Weight |
● All IE4000 models listed in Table 1: 6.35 pounds (2.88 kg)
● PWR-IE170W-PC-AC=: 3.88 pounds (1.76 kg)
● PWR-IE170W-PC-DC=: 3.7 pounds (1.67 kg)
● PWR-IE50W-AC=: 1.4 lb (0.65 kg)
● PWR-IE50W-AC-IEC=: 1.4 lb (0.65 kg)
● PWR-IE65W-PC-DC=: 2.6 (1.18 Kg)
● PWR-IE65W-PC-AC=: 2.7 (1.24 Kg)
|
Description |
Specification |
Forwarding rate |
Line rate for all ports and all packet sizes |
Number of queues |
4 egress |
Unicast MAC addresses |
16,000 |
IGMP multicast groups |
1,000 |
Number of VLANs |
1,000 |
IPv4 MAC security ACEs |
1,000 with default TCAM Template |
NAT translation |
Bidirectional, 128 unique subnet NAT translation entries, which can expand to tens of thousands of translated entries if designed properly |
LAN Base license (default) |
Features |
Layer 2 switching |
IEEE 802.1, 802.3, 802.3at, 802.3af standard, VTPv2, NTP, UDLD, CDP, LLDP, Unicast Mac filter, Flexlink, Resilient Ethernet Protocol (REP), VTPv3, EtherChannel, Voice VLAN, qinq tunneling, Industrial macro configuration |
Security |
SCP, SSH, SNMPv3, TACACS+, RADIUS Server/Client, MAC Address Notification, BPDU Guard, Port-Security, Private VLAN, DHCP Snooping, Dynamic ARP Inspection, IP Source Guard, 802.1x, Guest VLAN, MAC Authentication Bypass, 802.1x Multi-Domain Authentication, Storm Control, Trust Boundary, FIPS 140-2, ACT2, Secure boot, Full flexible Netflow2 |
Layer 2 multicast |
IGMPv1, v2, v3 Snooping, IGMP filtering, IGMP Querier |
Management |
Fast Boot, Express setup, Web Device Manager, Industrial Network Director (IND), MIB, Smartport, SNMP, syslog, storm control, unicast, multicast, broadcast, SPAN sessions, RSPAN, DHCP server, customized DOM (digital optical management), Embedded Event Manager (EEM), Plug-n-Play Agent, Port-based DHCP |
Industrial Ethernet |
CIP Ethernet/IP, Profinet v2, IEEE 1588 PTP v2, NTP to PTP translation, CIP Time Sync |
Quality of service |
Ingress Policing, Rate-Limit, Egress Queueing/shaping, AutoQoS, QoS, PROFINET QoS |
Layer 2 IPv6 |
IPv6 Host support, HTTP over IPv6, SNMP over IPv6 |
Layer 3 routing |
IPv4 Static Routing |
Industrial management |
Layer 2 switching with 1:1 static Network Address Translation (NAT) |
Redundancy |
Redundancy Ethernet Protocol ring (REP) Parallel Redundancy Protocol (PRP) Media Redundancy Protocol (MRP) ring, MRP Auto Manager (MAM) High Availability Seamless Redundancy (HSR) HSR-PRP (Dual RedBox mode) |
Utility |
Power Profile, dying gasp, GOOSE messaging, SCADA protocol classification, MODBUS TCP/IP, utility SmartPort macro, BFD, Ethernet OAM, IEEE 802.3ah, CFM (IEEE 802.1ag) |
IP Services license |
Additional features |
IP multicast |
PIM sparse mode (PIM-SM), PIM dense mode (PIM-DM), and PIM sparse-dense mode |
IP unicast routing protocols |
OSPF, EIGRP, BGPv4, IS-IS, RIPv2, Policy-Based Routing (PBR), HSRP |
Cisco Express forwarding |
Hardware routing architecture delivers extremely high-performance IP routing |
IPv6 routing |
RIPng, OSPFv6, and EIGRPv6 support |
Security |
IEEE 802.1AE MACsec, Cisco TrustSec®, SGT inline tagging and SGACL,Full flexible Netflow |
Virtualization |
VRF-lite |
License |
Description |
IE-LICENSE-SPARE |
Spare license for software upgrade ( L2 to L3 features or MRP protocols) |
L-IE4000-RTU= |
IE4000 Electronic software license upgrade from LAN base L2 to IP Services L3 features |
LIC-MRP-Manager= |
MRP ring manager license |
LIC-MRP-Client= |
MRP ring client license |
STK-RACK-DINRAIL= |
19” DIN Rail mount kit |
Type |
Standards |
Electromagnetic emissions |
FCC 47 CFR Part 15 Class A EN 55022A Class A VCCI Class A AS/NZS CISPR 22 Class A CISPR 11 Class A CISPR 22 Class A ICES 003 Class A CNS13438 Class A KN22 |
Electromagnetic immunity |
EN55024 CISPR 24 AS/NZS CISPR 24 KN24 EN 61000-4-2 Electro Static Discharge EN 61000-4-3 Radiated RF EN 61000-4-4 Electromagnetic Fast Transients N 61000-4-5 Surge EN 61000-4-6 Conducted RF EN 61000-4-8 Power Frequency Magnetic Field EN 61000-4-9 Pulse Magnetic Field EN 61000-4-11 AC Power Voltage EN 61000-4-18 Damped Oscillatory Wave EN-61000-4-29 DC Voltage Dips |
Industry standards |
EN 61000-6-1 Light Industrial EN 61000-6-2 Industrial EN 61000-6-4 Industrial EN 61326 Industrial Control EN 61131-2 Programmable Controllers Substation KEMA (IEEE 1613, IEC 61850-3) Marine DNV NEMA TS-2 (EMC, environmental, mechanical) IEEE 1613 Electric Power Stations Communications Networking IEC 61850-3 Electric Substations Communications Networking EN50155 Railway - Electronic Equipment on Rolling Stock (EMC, ENV, Mech) EN50121-4 Railway - Signaling and Telecommunications Apparatus EN50121-3-2 Railway - Apparatus for Rolling Stock ODVA Industrial EtherNet/IP PROFINET conformance B IP30 (per EN60529) |
Safety standards and certifications |
Information Technology Equipment: UL/CSA 60950-1 EN 60950-1 CB to IEC 60950-1 with all country deviations NOM to NOM-019-SCFI (through partners and distributor) Industrial Floor (Control Equipment): UL 508 CSA C22.2, No 142 Hazardous Locations: ANSI/ISA 12.12.01 CSA C22.2 No 213 IEC 60079-0, -15 IECEx test report EN 60079-0, -15 ATEX certification (Class I Zone 2) Cabinet enclosure required |
Operating environment |
Operating Temperature: -40C to +75C
● -40C to +70C (Vented Enclosure Operating)
● -40C to +60C (Sealed Enclosure Operating)
● -34C to +75C (Fan or Blower equipped Enclosure Operating)
EN 60068-2-1 EN 60068-2-2 EN 61163 Altitude: up to 15,000 feet |
Storage environment |
Temperature: -40 to +85 degrees C Altitude: 15,000 feet IEC 60068-2-14 |
Humidity |
Relative humidity of 5% to 95% non-condensing IEC 60068-2-3 IEC 60068-2-30 |
Shock and vibration |
IEC 60068-2-27 (operational shock, 50G, 11ms, Half Sine) IEC 60068-2-27 (Non-Operational Shock, 65-80G, 9ms, Trapezoidal) IEC 60068-2-6, IEC 60068-2-64, EN 61373 (Operational Vibration) IEC 60068-2-6, IEC 60068-2-64, EN 61373 (Non-operational Vibration) |
Corrosion |
ISO 9223: Corrosion class C3-Medium class C4-High EN 60068-2-52 (Salt Fog) EN 60068-2-60 (Flowing Mixed Gas) |
Others |
RoHS Compliance China RoHS Compliance TAA (Government) CE (Europe) |
Warranty |
Five-year limited HW warranty on all IE-4000 PIDs and all IE Power Supplies (see table 3 above). See link below for more details on warranty |
Mean time between failures (MTBF) |
IE-4000-4TC4G-E: 578, 730 Hours IE-4000-8T4G-E: 591, 070 Hours IE-4000-8S4G-E: 583, 700 Hours IE-4000-4T4P4G-E: 562, 300 Hours IE-4000-16T4G-E: 558, 310 Hours IE-4000-4S8P4G-E: 535, 880 Hours IE-4000-8GT4G-E: 591, 240 Hours IE-4000-8GS4G-E: 583, 700 Hours IE-4000-4GC4GP4G-E: 550, 940 Hours IE-4000-16GT4G-E: 558, 630 Hours IE-4000-8GT8GP4G-E: 519, 190 Hours IE-4000-4GS8GP4G-E: 536, 220 Hours |
Table 14. Management and standards
Description |
Specification |
|
IEEE standards |
● IEEE 802.1D MAC Bridges, STP
● IEEE 802.1p Layer2 COS prioritization
● IEEE 802.1q VLAN
● IEEE 802.1s Multiple Spanning-Trees
● IEEE 802.1w Rapid Spanning-Tree
● IEEE 802.1x Port Access Authentication
● IEEE 802.1AB LLDP
● IEEE 802.3ad Link Aggregation (LACP)
● IEEE 802.3af Power over Ethernet provides up to 15.4W DC power to each end device
● IEEE 802.3at Power over Ethernet provides up to 25.5W DC power to each end device
|
● IEEE 802.3af Power over Ethernet
● IEEE 802.3at Power over Ethernet Plus
● IEEE 802.3ah 100BASE-X SMF/MMF only
● IEEE 802.3x full duplex on 10BASE-T
● IEEE 802.3 10BASE-T specification
● IEEE 802.3u 100BASE-TX specification
● IEEE 802.3ab 1000BASE-T specification
● IEEE 802.3z 1000BASE-X specification
● IEEE 1588v2 PTP Precision Time Protocol
● IEEE 802.1AS PTP
● IEEE 802.1Qbv TSN
|
RFC compliance |
● RFC 768: UDP
● RFC 783: TFTP
● RFC 791: IPv4 protocol
● RFC 792: ICMP
● RFC 793: TCP
● RFC 826: ARP
● RFC 854: Telnet
● RFC 951: BOOTP
● RFC 959: FTP
● RFC 1157: SNMPv1
● RFC 1901,1902-1907 SNMPv2
● RFC 2273-2275: SNMPv3
● RFC 2571: SNMP Management
● RFC 1166: IP Addresses
● RFC 1256: ICMP Router Discovery
|
● RFC 1305: NTP
● RFC 1492: TACACS+
● RFC 1493: Bridge MIB Objects
● RFC 1534: DHCP and BOOTP interoperation
● RFC 1542: Bootstrap Protocol
● RFC 1643: Ethernet Interface MIB
● RFC 1757: RMON
● RFC 2068: HTTP
● RFC 2131, 2132: DHCP
● RFC 2236: IGMP v2
● RFC 3376: IGMP v3
● RFC 2474: DiffServ Precedence
● RFC 3046: DHCP Relay Agent Information Option
● RFC 3580: 802.1x RADIUS
● RFC 4250-4252 SSH Protocol
|
SNMP MIB objects |
● BRIDGE-MIB
● CALISTA-DPA-MIB
● CISCO-ACCESS-ENVMON-MIB
● CISCO-ADMISSION-POLICY-MIB
● CISCO-AUTH-FRAMEWORK-MIB
● CISCO-BRIDGE-EXT-MIB
● CISCO-BULK-FILE-MIB
● CISCO-CABLE-DIAG-MIB
● CISCO-CALLHOME-MIB
● CISCO-CAR-MIB
● CISCO-CDP-MIB
● CISCO-CIRCUIT-INTERFACE-MIB
● CISCO-CLUSTER-MIB
● CISCO-CONFIG-COPY-MIB
● CISCO-CONFIG-MAN-MIB
● CISCO-DATA-COLLECTION-MIB
● CISCO-DHCP-SNOOPING-MIB
● CISCO-EMBEDDED-EVENT-MGR-MIB
● CISCO-ENTITY-ALARM-MIB
● CISCO-ENTITY-SENSOR-MIB
● CISCO-ENTITY-VENDORTYPE-OID-MIB
● CISCO-ENVMON-MIB
● CISCO-ERR-DISABLE-MIB
● CISCO-FLASH-MIB
● CISCO-FTP-CLIENT-MIB
● CISCO-IF-EXTENSION-MIB
● CISCO-IGMP-FILTER-MIB
● CISCO-IMAGE-MIB
● CISCO-IP-STAT-MIB
● CISCO-LAG-MIB
● CISCO-LICENSE-MGMT-MIB
● CISCO-MAC-AUTH-BYPASS-MIB
● CISCO-MAC-NOTIFICATION-MIB
● CISCO-MEMORY-POOL-MIB
● CISCO-PAE-MIB
● CISCO-PAGP-MIB
● CISCO-PING-MIB
● CISCO-PORT-QOS-MIB
● CISCO-PORT-SECURITY-MIB
● CISCO-PORT-STORM-CONTROL-MIB
● CISCO-PRIVATE-VLAN-MIB
● CISCO-PROCESS-MIB
● CISCO-PRODUCTS-MIB
● CISCO-RESILIENT-ETHERNET-PROTOCOL-MIB
● CISCO-RTTMON-ICMP-MIB
● CISCO-RTTMON-IP-EXT-MIB
● CISCO-RTTMON-MIB
● CISCO RTTMON-RTP-MIB
|
● CISCO RTTMON-RTP-MIB
● CISCO-SNMP-TARGET-EXT-MIB
● CISCO-STACK-MIB
● CISCO-STACKMAKER-MIB
● CISCO-STP-EXTENSIONS-MIB
● CISCO-SYSLOG-MIB
● CISCO-TCP-MIB
● CISCO-UDLDP-MIB
● CISCO-VLAN-IFTABLE-RELATIONSHIP-MIB
● CISCO-VLAN-MEMBERSHIP-MIB
● CISCO-VTP-MIB
● ENTITY-MIB
● ETHERLIKE-MIB
● HC-RMON-MIB
● IEEE8021-PAE-MIB
● IEEE8023-LAG-MIB
● IF-MIB
● IP-FORWARD-MIB
● LLDP-EXT-MED-MIB
● LLDP-EXT-PNO-MIB
● LLDP-MIB
● NETRANGER
● NOTIFICATION-LOG-MIB
● OLD-CISCO-CHASSIS-MIB
● OLD-CISCO-CPU-MIB
● OLD-CISCO-FLASH-MIB
● OLD-CISCO-INTERFACES-MIB
● OLD-CISCO-IP-MIB
● OLD-CISCO-MEMORY-MIB
● OLD-CISCO-SYS-MIB<
● OLD-CISCO-SYSTEM-MIB
● OLD-CISCO-TCP-MIB
● OLD-CISCO-TS-MIB
● RMON-MIB
● RMON2-MIB
● SMON-MIB
● SNMP-COMMUNITY-MIB
● SNMP-FRAMEWORK-MIB
● SNMP-MPD-MIB
● SNMP-NOTIFICATION-MIB
● SNMP-PROXY-MIB
● SNMP-TARGET-MIB
● SNMP-USM-MIB
● SNMP-VIEW-BASED-ACM-MIB
● SNMPv2-MIB
● TCP-MIB
● UDP-MIB
|
Part number |
Specification |
SFP type |
Max distance |
Cable type |
Temp range* |
DOM support |
GLC-FE-100FX-RGD= |
100BASE-FX |
FE |
2km |
MMF |
IND |
Yes |
GLC-FE-100LX-RGD= |
100BASE-LX10 |
FE |
10km |
SMF |
IND |
Yes |
GLC-FE-100FX= |
100BASE-FX |
FE |
2km |
MMF |
COM |
No |
GLC-FE-100LX= |
100BASE-LX10 |
FE |
10km |
SMF |
COM |
No |
GLC-FE-100EX= |
100BASE-EX |
FE |
40km |
SMF |
COM |
No |
GLC-FE-100ZX= |
100BASE-ZX |
FE |
80km |
SMF |
COM |
No |
GLC-FE-100BX-D= |
100BASE-BX10 |
FE |
10km |
SMF |
COM |
No |
GLC-FE-100BX-U= |
100BASE-BX10 |
FE |
10km |
SMF |
COM |
Yes |
GLC-SX-MM-RGD= |
1000BASE-SX |
GE |
550m |
MMF |
IND |
Yes |
GLC-LX-SM-RGD= |
1000BASE-LX/LH |
GE |
550m/10km |
MMF/SMF |
IND |
Yes |
GLC-ZX-SM-RGD= |
1000BASE-ZX |
GE |
70km |
SMF |
IND |
Yes |
GLC-BX40-U-I= |
1000BASE-BX40 |
GE |
40km |
SMF |
IND |
Yes |
GLC-BX40-D-I= |
1000BASE-BX40 |
GE |
40km |
SMF |
IND |
Yes |
GLC-BX40-DA-I= |
1000BASE-BX40 |
GE |
40km |
SMF |
IND |
Yes |
GLC-BX80-U-I= |
1000BASE-BX80 |
GE |
80km |
SMF |
IND |
Yes |
GLC-BX80-D-I= |
1000BASE-BX80 |
GE |
80km |
SMF |
IND |
Yes |
GLC-SX-MMD= |
1000BASE-SX |
GE |
550m |
MMF |
EXT |
Yes |
GLC-LH-SMD= |
1000BASE-LX/LH |
GE |
550m/10km |
MMF/SMF |
EXT |
Yes |
GLC-EX-SMD= |
1000BASE-EX |
GE |
40km |
SMF |
EXT |
Yes |
GLC-ZX-SMD= |
1000BASE-ZX |
GE |
70km |
SMF |
EXT |
Yes |
GLC-BX-D= |
1000BASE-BX10 |
GE |
10km |
SMF |
COM |
Yes |
GLC-BX-U= |
1000BASE-BX10 |
GE |
10km |
SMF |
COM |
Yes |
CWDM-SFP-xxxx= (8 freq) |
CWDM 1000BASE-X |
GE |
|
SMF |
COM |
Yes |
DWDM-SFP-xxxx= (40 freq) |
DWDM 1000BASE-X |
GE |
|
SMF |
COM |
Yes |
SFP-GE-S= |
1000BASE-SX |
GE |
550m |
MMF |
EXT |
Yes |
SFP-GE-L= |
1000BASE-LX/LH |
GE |
550m/10km |
MMF/SMF |
EXT |
Yes |
SFP-GE-Z= |
1000BASE-ZX |
GE |
70km |
SMF |
EXT |
Yes |
GLC-SX-MM= |
1000BASE-SX |
GE |
550m |
MMF |
COM |
No |
GLC-LH-SM= |
1000BASE-LX/LH |
GE |
550m/10km |
MMF/SMF |
COM |
No |
GLC-ZX-SM= |
1000BASE-ZX |
GE |
70km |
SMF |
COM |
Yes |
GLC-TE= |
1000BASE-T |
GE |
100m |
Copper |
EXT |
NA |
GLC-T-RGD= |
1000BASE-T |
GE |
100m |
Copper |
IND |
NA |
Cisco IE4000 series |
|||
Network Device |
Transceiver Model |
Minimum Software Release Required |
|
DOM Support |
Software Release |
||
IE-4000-4TC4G-E |
GLC-SX-MM-RGD |
15.2(2)EA |
15.2(2)EA |
GLC-SX-MM |
— |
15.2(2)EA |
|
GLC-BX40-U-I |
15.2(4)EA |
15.2(4)EA |